| ●With Stabilizer Function | |||
| ●Wide Input Voltage Range | |||
| ●Wide Input Frequency Range | |||
| ●High/Low Voltage Protection, Overload/Short Protection | |||
| ●Cool start computer even there isnt main power | |||
| ●Automatic recharge even UPS is off | |||
| ●Automatic restart | |||
| ●Beeping Alarm on Battery, Battery Low and Overload | |||
| ●Beeping Selection | |||
| ●Intelligent Battery Management | |||
| ●Intelligent LCD Display | |||
| ●Smart RS232& RJ11& USBOption | |||
| ●Compatibility with generators |
| Overview |
| Product | Requirements | Model 1 | Model 2 | Model 3 | Model 4 | Model 5 | Model 6 |
| Power (VA) | PCA-500 | PCA-650 | PCA-800 | PCA-1000 | PCA-1200 | PCA-1500 | |
| Input | Voltage | 80-150VAC / 145-290VAC ±5V | |||||
| Frequency | 60/50Hz+/-10% | ||||||
| Output | Voltage (AC Mode) | 105-135VAC / 190-250VAC | |||||
| Voltage (Inverter Mode) | 120VAC / 220VAC ±5% | ||||||
| Capacity | 500VA/300W | 650VA/360W | 800/480W | 1000VA/600W | 1200/720W | 1500VA/880W | |
| Frequency (Inverter Mode) | 60/50Hz+/-0.5Hz | ||||||
| Transfer Time | 2ms typical | ||||||
| Generator connection | Normal Working under the Generator | ||||||
| Waveform | modified-Sinewave | ||||||
| Protection | Spike & Surge Suppression | yes | |||||
| Over/Under Volt. | Switch to Bat.O / Pwhen Mains over regulation range | ||||||
| Over load /short Circuit | Fuse & current limited for both Mains and Battery modes | ||||||
| Battery | Type | Lead-Acid maintenance-free | |||||
| Dc Bus | 12V7.0Ah | 12V9.0Ah | 12V7.0Ah | 12V9.0Ah | |||
| Number | 1 PC | 1 | 2 PCS | ||||
| Recharge time | 8hours≥90% | ||||||
| Back up time(one PC) | 8-15mins | 10-18mins | 15-25mins | 20-30mins | 20-30mins | 25-45mins | |
| Physical | Weight (KGs) | 5 | 5.5 | 6 | 10.5 | 11 | 11.5 |
| ShippingWt. | 5.6 | 6 | 6.5 | 11 | 11.5 | 12 | |
| Product Dimensions (mm) | 335*95*160 | 355*120*195 | |||||
| Packing Dimensions (mm) | 395*360*230 mm/ 2 PCS in 1 Carton | 435*395*275/ 2 PCS in 1 Carton | |||||
| Soft ware | RS232 or USB optionWindows & NT | Auto save & shut down | |||||
| Function | Cold start | UPS Start The Computer Even there Is no Main Power | |||||
| Automatic Charge | Automatic Charge when UPS is off | ||||||
| Automatic Restart | Automatic Restart if main power coming within one hour | ||||||
| Voltage display | 220v/230v Optionalfollowing the real capacity | ||||||
| Frequency | 50HZ/60HZ Optioanl following the real | ||||||
| Beeping | During the battery mode ,the beeping optional | ||||||
| Efficiency | AC-AC | 1 | |||||
| DC-AC | 0.6 | ||||||
| Acoustic | Noise level | ≤45dB | |||||
| Environmental | Temperature | -5-45 DegreeC | |||||
| Humidity | 20% to 90% | ||||||
| Power Outlets | No. and types | 2SOCKETS | 3 SOCKETS | ||||